Summary for Test 2019-02-07-5-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 213074
DEA: 044G8904
EFIS: 0413000059
DIST-CO-RTE-PM04-CC-580-5.8
Award Date05/10/2018
Closeout Date03/12/2020
Work DescriptionBIDGE SEISMIC RETROFIT
Location DescriptionCONTRA COSTA COUNTY IN RICHMOND AT SCOFIELD AVENUE UNDERCROSSING
QA Service Level1 (Verified on 02/13/2018)

Sample Information

Sample Taken Date02/07/2019 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing02/07/2019 Sample typeQuality Assurance
A brief description of the sampleConnection Bolts The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byAndre
Last name of sampler or witnessed byTotari Title of samplerAMR
Telephone number of sampler(510) 730-0387 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCosmec
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)410347C
Washer Mfg. Lot Number(s)D5910 Bolt SpecificationA325
Bolt Length(s)7.5 Nut SpecificationA194
Washer SpecificationF436 Finish
Diameter/Size1 Bolt Mfg. Lot Number373303
Rocap Test Requirement(s) Lubricant Requirements(s)Green
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2019-02-07-5
DIME Test ID: 2019-02-07-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-02-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/14/2019
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11A373303A1\"90444402.310A325Steve

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 2/15/2019 ✔