Summary for Test 2019-02-07-4-2
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 213074 DEA: 044G8904 EFIS: 0413000059 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-580-5.8 |
| Award Date | 05/10/2018 |
| Closeout Date | 03/12/2020 |
| Work Description | BIDGE SEISMIC RETROFIT |
| Location Description | CONTRA COSTA COUNTY IN RICHMOND AT SCOFIELD AVENUE UNDERCROSSING |
| QA Service Level | 1 (Verified on 02/13/2018) |
Sample Information
| Sample Taken Date | 02/07/2019 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 02/07/2019 | Sample type | Quality Assurance |
| A brief description of the sample | Anchor Rods | The quantity of what the sample constitutes | 13 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Andre |
| Last name of sampler or witnessed by | Totari | Title of sampler | ASMR |
| Telephone number of sampler | (510) 730-0387 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Cosmec | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | DL18104836, DL16102749, 176411 | Nut Mfg. Lot Number(s) | 381629A, |
| Washer Mfg. Lot Number(s) | 312021 | Bolt Specification | A449 threaded rod |
| Bolt Length(s) | 16", 12.5", 12", 8.75", 7.5" | Nut Specification | A194-2H HDG |
| Washer Specification | F436 HDG | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-02-07-4
DIME Test ID: 2019-02-07-4-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-02-22
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Steve
Date of test: 02/13/2019
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 1B | A449 rod Axial 1\" x 12.5\" | 0.606 | 80344 | 357 | 132581 | 115361 | 69909 | A449 rod axial |
General comments (publicly viewable) (Max 1000 characters): A449 rod axial
Test Graph
Source: Partner Data Point FileTest was verified on 2/15/2019 ✔
