Summary for Test 2017-07-10-1-12

Test performed: ASTM C451-13

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/10/2017 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing07/10/2017 Sample typeProficiency
A brief description of the sampleCCRL 205 The quantity of what the sample constitutes1 box
From where was the sample collectedFabricator First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM178205
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCCRL
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialType II Cement

Test Details

DIME Sample ID: 2017-07-10-1
DIME Test ID: 2017-07-10-1-12
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C451-13: Standard Test Method for Early Stiffening of Hydraulic Cement (Paste Method)
Test Release Date: 2019-02-19

Test Results


Input Type: Calculated
Tester's full name: Benjamin Lenz
Date of test: 02/12/2019
Percent final penetration: 64 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/12/2019