Summary for Test 2019-01-18-17-3

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 212910
DEA: 080K2914
EFIS: 0812000098
DIST-CO-RTE-PM08-SBD-10-30.9/33.3
Award Date03/06/2018
Closeout Date09/04/2019
Work DescriptionLANE REPLACEMENT
Location DescriptionSAN BERNARDINO COUNTY IN REDLANDS FROM ORANGE STREET UNDERCROSSING TO REDLANDS BLVD OFF-RAMP UNDERCROSSING
QA Service Level1 (Verified on 05/02/2018)

Sample Information

Sample Taken Date01/18/2019 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing01/19/2019 Sample typeDepartment Acceptance
A brief description of the sampleConcrete beams The quantity of what the sample constitutes3
From where was the sample collectedJob Site First name of sampler or witnessed byDenis
Last name of sampler or witnessed bySostrom Title of sampler
Telephone number of sampler Laboratory sample identification19RA, 19RB, 19RC
Linked DIME Sample ID The fabricator/manufacturer/facility nameCemex Redlands
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1555211
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedTT1
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2019-01-18-17
DIME Test ID: 2019-01-18-17-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2019-02-13

Test Results


Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: A Alzubi
Date of test: 01/29/2019
Identification number: 19RC
Width of specimen: 6.125 inch
Depth of specimen: 6.125 inch
Span length of specimen: 18 inch
Maximum load applied: 11100 lb
Curing history and apparent moisture condition of the specimen: Sand Pit
If specimen was capped, ground or if leather shims were used: n/a
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 11 days
Age of specimen in hours: no data
Modulus of rupture: 900 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/13/2019 ✔