Summary for Test 2019-01-10-5-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 210735 DEA: 071193U4 EFIS: 0713000007 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-10-37.2/42.4 |
| Award Date | 11/16/2015 |
| Closeout Date | 07/11/2022 |
| Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
| Location Description | IN LA COUNTY FROM CITRUS STREET IN WEST COVINA TO ROUTE 57 IN POMONA |
| QA Service Level | 1 (Verified on 03/07/2016) |
Sample Information
| Sample Taken Date | 01/10/2019 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/14/2019 |
| Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Rodriguez |
| Title of sampler | Field Technician | Telephone number of sampler | |
| Laboratory sample identification | 946-110 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | HOLIDAY ROCK | Transportation Laboratory (TL) Number | 2019110 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | tw 2118 barrier rail typy 736 sta 89 89 to sta 91 24 | |
| Structure name | tw 2118 barrier rail typy 736 sta 89 89 to sta 91 24 | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CM5645 |
|---|---|---|---|
| The truck number from where the sample was collected | 276 | The batch plant ticket number from where the sample was collected | 1 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | ATKINSON |
| A detailed description of where the material sample was collected | truck | Where the material sample would have been placed if not sampled | tw 2118 barrier rail typy 736 sta 89 89 to sta 91 24 |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2019-01-10-5
DIME Test ID: 2019-01-10-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2019-02-15
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 02/07/2019
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 121790 lb
Maximum load on cylinder 2: 121450 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4308.1 psi
Compressive strength of cylinder 2: 4296.1 psi
Compressive strength (to nearest 10 psi): 4300 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/8/2019 ✔