Summary for Test 2019-01-21-6-2
Test performed: AASHTO T96-02r10Project Information
| Project Identifiers | Project ID: 213469 DEA: 024C40V4 EFIS: 0218000125 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-5-R3.8/R11.7 |
| Award Date | 11/06/2018 |
| Closeout Date | 08/16/2023 |
| Work Description | WIDEN TO 6 LANES, BRIDGE REPLACEMENT AND WIDENING AND ROADWAY REHAB |
| Location Description | SHASTA COUNTY IN AND NEAR ANDERSON FROM ROUTE 5/273 SEPARATION TO 0.4 MILE SOUTH OF CHURN CREEK ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 12/31/2018) |
Sample Information
| Sample Taken Date | 01/21/2019 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2019 |
| Sample type | Quality Control | A brief description of the sample | Combined 3/4-inch Type A (Untreated, Virgin) |
| The quantity of what the sample constitutes | Mix Design | From where was the sample collected | Source |
| First name of sampler or witnessed by | CGI | Last name of sampler or witnessed by | CGI |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 19-1001 314 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Fawndale Rock Quarry | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0017::FAWNDALE ROCK QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | 19-1001.314 |
| The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | JMF 19-01-S1a | Lot number | 0 |
| Sublot number | 0 | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-01-21-6
DIME Test ID: 2019-01-21-6-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2019-02-06
Test Results
Input Type: Calculated
Tester's full name: CGI
Date of test: 01/21/2019
Grading designation: B
Percent loss after 100 revolutions: 3 %
Percent loss after 500 revolutions: 12 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/6/2019 ✔