Summary for Test 2019-01-11-8-9
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 213718 DEA: 071XJ704 EFIS: 0719000092 |
|---|---|
| DIST-CO-RTE-PM | 07-VEN-1-4.75/5.25, 4.75-5.25 |
| Award Date | 10/19/2018 |
| Closeout Date | 04/30/2020 |
| Work Description | Repair eroded support slopes, shoulders and utilities and install RSP to prevent erosion from high surf |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 04/30/2020) |
Sample Information
| Sample Taken Date | 01/11/2019 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/15/2019 |
| Sample type | Department Acceptance | A brief description of the sample | HMA-A 3/4" R15 PG64-16/10 (0.5% LAS) |
| The quantity of what the sample constitutes | unknown | From where was the sample collected | Source |
| First name of sampler or witnessed by | unknown | Last name of sampler or witnessed by | unknown |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | vulcan saticoy | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Not set |
| Sublot number | Not set | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2019-01-11-8
DIME Test ID: 2019-01-11-8-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-01-31
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Anthony Diaz
Date of test: 01/17/2019
Test procedure used?: Method B
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 2088.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1977.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.33 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 538 F
Corrected Asphalt Binder Content: 5.01 %
General comments (publicly viewable) (Max 1000 characters): CF (binder correction and temperature compensation)
Test was verified on 1/31/2019 ✔