Summary for Test 2018-09-19-13-1

Test performed: ASTM C78-10

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date09/19/2018 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing10/17/2018 Sample typeQuality Assurance
A brief description of the samplecasting concrete beams The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byLarry
Last name of sampler or witnessed byFrancisco Title of samplerTE Civil
Telephone number of sampler Laboratory sample identificationset 15
Linked DIME Sample ID The fabricator/manufacturer/facility nameKiewitt Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB18-0029
The truck number from where the sample was collected125 The batch plant ticket number from where the sample was collectedna
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleKIEWITT
A detailed description of where the material sample was collectedstation 634 75 WB Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-09-19-13
DIME Test ID: 2018-09-19-13-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: ASTM C78-10: Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading)
Test Release Date: 2019-02-01

Test Results


Unit system used?: US Units
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Input Type: Measured
Tester's full name: Minh Pham
Date of test: 10/17/2018
Identification number: 15A
Width of specimen: 6 inch
Depth of specimen: 6.0938 inch
Span length of specimen: 18 inch
Maximum load applied: 8910 lb
Curing history and apparent moisture condition of the specimen: sand pit
If specimen was capped, ground or if leather shims were used: no
Defects in specimen: no
Age of specimen: 28 days
Modulus of rupture: 720 psi
General comments (publicly viewable) (Max 1000 characters): 760 psi

Test was verified on 1/25/2019 ✔