Summary for Test 2019-01-16-10-1
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 211967 DEA: 101E8904 EFIS: 1016000093 |
|---|---|
| DIST-CO-RTE-PM | 10-SJ-5-26.5/27.0 |
| Award Date | 03/02/2017 |
| Closeout Date | 01/24/2020 |
| Work Description | REPAIR BRIDGE CROSSFRAMES. |
| Location Description | SAN JOAQUIN COUNTY IN STOCKTON AT STOCKTON CHANNEL VIADUCT |
| QA Service Level | 1 (Verified on 07/24/2017) |
Sample Information
| Sample Taken Date | 01/16/2019 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/21/2019 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG Rocap Assembiy |
| The quantity of what the sample constitutes | 64 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
| Title of sampler | QAI | Telephone number of sampler | 510-693-3545 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cordova Bolt | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L02-003-19 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 304-19-2 |
|---|---|---|---|
| Heat Number(s) | 100890078 | Nut Mfg. Lot Number(s) | 411793D |
| Washer Mfg. Lot Number(s) | 0818-936 | Bolt Specification | A325 |
| Bolt Length(s) | 9-1/2" | Nut Specification | A563 |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 1" | Bolt Mfg. Lot Number | 404965A |
| Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-01-16-10
DIME Test ID: 2019-01-16-10-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-02-01
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/25/2019
UTM: 400KIP
Temperature: no data
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 7A | 404965A | 1\" | 87225 | 388 | 10 | A325 | Fred |
General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point FileTest was verified on 1/25/2019 ✔