Summary for Test 2019-01-15-2-8
Test performed: ASME B1.2-83r01Project Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 01/15/2019 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2019 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A325 3/4 - 4" |
| The quantity of what the sample constitutes | 135 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
| Title of sampler | QA Inspector | Telephone number of sampler | 707-342-8602 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Industrial Bolt and Supply | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-005-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | RC0033427 |
|---|---|---|---|
| Heat Number(s) | 10514140 | Nut Mfg. Lot Number(s) | 29387-S |
| Washer Mfg. Lot Number(s) | D5483 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 4" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | Galvanized |
| Diameter/Size | 3/4" x 4" | Bolt Mfg. Lot Number | BG1058 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2019-01-15-2
DIME Test ID: 2019-01-15-2-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Plug Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Plug Gage)
Test Release Date: 2019-01-30
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 01/23/2019
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 29387-S-6214786102
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: U DH
Size: .750 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/23/2019 ✔