Summary for Test 2019-01-15-1-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
| Award Date | 12/06/2010 |
| Closeout Date | 06/30/2021 |
| Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
| QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
| Sample Taken Date | 01/15/2019 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 01/17/2019 | Sample type | Quality Assurance |
| A brief description of the sample | ASTM A325 3/4-3-1/2 | The quantity of what the sample constitutes | 65 |
| From where was the sample collected | Distributor | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | QA Inspector |
| Telephone number of sampler | 707-342-8602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Industrial Bolt and Supply | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-005-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | RC0033426 |
|---|---|---|---|
| Heat Number(s) | 10543000 | Nut Mfg. Lot Number(s) | 29387-S |
| Washer Mfg. Lot Number(s) | D5483 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 3-1/2" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | Galvanized |
| Diameter/Size | 3/4" x 3-1/2" | Bolt Mfg. Lot Number | BG1183 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2019-01-15-1
DIME Test ID: 2019-01-15-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2019-01-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 01/23/2019
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 29387-5-6214786102 | ?\" | 50818 | 226.05 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 1/23/2019 ✔