Summary for Test 2018-06-04-35-1
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212741 DEA: 020E1804 EFIS: 0200000022 |
---|---|
DIST-CO-RTE-PM | 02-PLU-89-29.8/30.2 |
Award Date | 12/13/2017 |
Closeout Date | 12/17/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | PLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY |
QA Service Level | 1 (Verified on 12/06/2017) |
Sample Information
Sample Taken Date | 06/04/2018 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2018 |
Sample type | Verification | A brief description of the sample | RAP |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Derrick | Last name of sampler or witnessed by | Curry |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D77438 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Sierra Cascade Aggregate and Asphalt Products | Transportation Laboratory (TL) Number | 894777 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF 18-04-S3 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Dig It Construction |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | Unknown |
RAP Stockpile | Stockpile Size (tons) | Unknown | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2018-06-04-35
DIME Test ID: 2018-06-04-35-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2019-01-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Darrell Valasek
Date of test: 06/08/2018
Specific Gravity for Sample 1: 2.476
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/22/2019 ✔