Summary for Test 2019-01-11-1-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211848 DEA: 112T2174 EFIS: 1116000131 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-R37.4 - R46.5 |
Award Date | 12/22/2016 |
Closeout Date | Not set |
Work Description | (Alternative Delivery) CMGC, San Elijo Highway Bridge Replacement. Replace the San Elijo lagoon highway bridge, construct HOV lanes, construct bike and pedestrian trails and bridge, build multi-use facility at Manchester Ave. |
Location Description | IN SAN DIEGO COUNTY IN SOLANA BEACH AND ENCINITAS FROM 0.1 MILE NORTH OF LOMAS SANTA FE DRIVE OVERCROSSING TO 0.2 MILE SOUTH OF BIRMINGHAM DRIVE OVERCROSSING |
QA Service Level | 1 (Verified on 01/31/2017) |
Sample Information
Sample Taken Date | 01/11/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/17/2019 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 150 | From where was the sample collected | Source |
First name of sampler or witnessed by | Prakash | Last name of sampler or witnessed by | Patel |
Title of sampler | TET | Telephone number of sampler | 5626654686 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L1100119 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | xxxxx |
Hoop Manufacturer Lot Number(s) | xxxxx | Material Standard Code | ASTM A706 |
Material Grade | 40 | Rebar Size | 7 |
Diameter of Hoop | 5'-5" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | xxx |
Welding Company | TNT Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2019-01-11-1
DIME Test ID: 2019-01-11-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2019-01-25
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 01/18/2019
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 38 | #7/22mm | 0.6 | 57350 | 95580 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample