Summary for Test 2018-05-24-11-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212562
DEA: 024G5504
EFIS: 0214000036
DIST-CO-RTE-PM02-SIS-5-2.7/R11.4
Award Date03/12/2018
Closeout Date10/05/2020
Work DescriptionRECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS
Location DescriptionSISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS
QA Service Level1 (Verified on 04/04/2018)

Sample Information

Sample Taken Date05/24/2018 Sample Unique Key11
Date that the sample was received by the laboratory/organization performing the testing05/24/2018 Sample typeVerification
A brief description of the sampleTreated Virgin Aggregate The quantity of what the sample constitutesJMF Verification
From where was the sample collectedManufacturer First name of sampler or witnessed byChandler
Last name of sampler or witnessed byFaeth Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationD77420
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameFawndale Rock and Asphalt
Transportation Laboratory (TL) Number897214 Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-14-S2
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0017::FAWNDALE ROCK QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sample18-1001.305-15Neat
The plant numberUnknown A detailed description of where the material sample was collectedCold Feed
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 18-14-S2 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-24-11
DIME Test ID: 2018-05-24-11-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-12-19

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Darrell Valasek
Date of test: 05/29/2018
Cumulative Percent Passing
%
100 %
100 %
99.6 %
82.5 %
71.4 %
55.9 %
46.7 %
27.4 %
16.5 %
11.1 %
7.9 %
6 %
4.76 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/19/2018 ✔