Summary for Test 2018-04-25-20-1
Test performed: CTM 204-June 2010Project Information
| Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
| Award Date | 03/12/2018 |
| Closeout Date | 10/05/2020 |
| Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
| Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
| QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
| Sample Taken Date | 04/25/2018 | Sample Unique Key | 20 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/27/2018 |
| Sample type | Verification | A brief description of the sample | Sized, Untreated, Virgin Aggregatetes |
| The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Source |
| First name of sampler or witnessed by | Chandler | Last name of sampler or witnessed by | Faeth |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | D77341 | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Fawndale Rock Quarry | Transportation Laboratory (TL) Number | 001555 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF 18-14-S2 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-45-0017::FAWNDALE ROCK QUARRY |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | 18-1001.305-15Neat |
| The plant number | Unknown | A detailed description of where the material sample was collected | Lab-Batched from Sized Untreated Aggregate Stockpiles |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | JMF 18-14-S2 | Lot number | Not set |
| Sublot number | Not set | Aggregate Mix Number | Not set |
| HMA Pay | No |
Test Details
DIME Sample ID: 2018-04-25-20
DIME Test ID: 2018-04-25-20-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2018-12-19
Test Results
The test method used?: Plastic Index
Input Type: Calculated
Tester's full name: Mike Cruz
Date of test: 05/22/2018
Liquid Limit (LL): 0 %
Plastic Limit (PL): 0 %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/19/2018 ✔