Summary for Test 2014-05-31-7306900-2

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 209511
DEA: 080Q7403
EFIS: 0800020456
DIST-CO-RTE-PM08-SBD-15-15.4/30.8
Award Date10/29/2013
Closeout DateNot set
Work DescriptionDesign Build project provides pavement rehabilitation (including ramps) on I-15 near Cajon Pass, CA.
Location DescriptionOn I-15 from 0.4 mile north of Kenwood Avenue to 0.3 mile south of West Hesperia OH
QA Service Level1 (Verified on 04/03/2014)

Sample Information

Sample Taken Date05/31/2014 Sample Unique Key7306900
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2014
Sample typePreliminary A brief description of the sampleSoil
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byAbdel Last name of sampler or witnessed byNaser
Title of samplerTE Telephone number of samplerNot set
Laboratory sample identification4151B Linked DIME Sample IDNot set
The fabricator/manufacturer/facility namePM 26.2 S/B I-15 Lane 4 Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleNot set
The fabricator/manufacturer designation for the sampleNot set A detailed description of where the material sample was collectedPM 26.2 S/B I-15 Lane 4
Where the material sample would have been placed if not sampledNot set

Test Details

DIME Sample ID: 2014-05-31-7306900
DIME Test ID: 2014-05-31-7306900-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2015-02-20

Test Results


The test method used?: Laboratory Resistivity Test
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 06/05/2014
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/20/2015