Summary for Test 2018-11-15-4-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212743 DEA: 030H26U4 EFIS: 0317000247 |
---|---|
DIST-CO-RTE-PM | 03-PLA-65-R5.0/R6.6 |
Award Date | 02/14/2018 |
Closeout Date | 10/21/2022 |
Work Description | NORTHBOUND WIDENING AND RAMP IMPROVEMENTS. |
Location Description | PLACER COUNTY IN AND NEAR ROSEVILLE AND ROCKLIN FROM 0.1 MILE SOUTH OF EAST ROSEVILLE VIADUCT TO 0.5 MILE SOUTH OF PLEASANT GROVE BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 12/18/2017) |
Sample Information
Sample Taken Date | 11/15/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2018 |
Sample type | Quality Assurance | A brief description of the sample | HRC 500 510 Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Russ | Last name of sampler or witnessed by | Jimmer |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 8 | Coupler Model | 500 / 510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | NF100794642 | Rebar Heat Number(s) | 4073641 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-11-15-4
DIME Test ID: 2018-11-15-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-11-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/15/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #8/25mm | 0.79 | 0 | 77051 | 97533 | Necking Ok | Brian |
General comments (publicly viewable) (Max 1000 characters): Necking Ok
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/16/2018 ✔