Summary for Test 2018-11-08-1-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 11/08/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/08/2018 |
| Sample type | Quality Assurance | A brief description of the sample | structural concrete |
| The quantity of what the sample constitutes | 250cy | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Brett | Last name of sampler or witnessed by | soldano |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Teichert Woodland | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
| Structure name | Unknown | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 123456 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 123456 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | wheelbarrow | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-11-08-1
DIME Test ID: 2018-11-08-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-11-08
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Brian Teh
Date of test: 11/08/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.09 in
Average diameter of cylinder 2: 6.78 in
Maximum load on cylinder 1: 10000 lb
Maximum load on cylinder 2: 15000 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 10 days
Cross sectional area of cylinder 1: 29.13 in^2
Cross sectional area of cylinder 2: 36.1 in^2
Compressive strength of cylinder 1: 343.3 psi
Compressive strength of cylinder 2: 415.5 psi
Compressive strength (to nearest 10 psi): 380 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/8/2018 ✔