Summary for Test 2018-10-29-1-1
Test performed: ASTM A970-15e1Project Information
| Project Identifiers | Project ID: 212376 DEA: 044G8504 EFIS: 0413000052 |
|---|---|
| DIST-CO-RTE-PM | 04-SM-1-R44.1 |
| Award Date | 04/12/2018 |
| Closeout Date | 09/01/2020 |
| Work Description | REPLACE PEDESTRIAN OVERCROSSING |
| Location Description | SAN MATEO COUNTY IN PACIFICA AT THE SAN JOSE AVENUE PEDESTRIAN OVERCROSSING |
| QA Service Level | 1 (Verified on 05/23/2018) |
Sample Information
| Sample Taken Date | 10/29/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/01/2018 | Sample type | Quality Assurance |
| A brief description of the sample | HRC 150 Headed Reinforcement | The quantity of what the sample constitutes | 1 lot of 10 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | David |
| Last name of sampler or witnessed by | Weeks | Title of sampler | |
| Telephone number of sampler | 310-883-8369 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | HRC Fountain Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-094-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 6503216102 | Head Manufacturer Lot Number(s) | B1123978 |
| Rebar Size | 6 | Headed Bar Model Name | HRC 150 |
| Size of Head | Reduced Size - 4x | Head Connection Type | |
| Head Shape | Circular | Rebar Manufacturer | Gerdau |
| Head Manufacturer | HRC | Head Fabricator | HRC Fountain Valley |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2018-10-29-1
DIME Test ID: 2018-10-29-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-11-09
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 11/02/2018
UTM: 400KIP
Temperature: 72 F
| Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|
| 1 | 2 | 0.44 | 43970 | 99930 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 11/2/2018 ✔