Summary for Test 2018-10-12-13-3
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/12/2018 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/23/2018 |
Sample type | Quality Assurance | A brief description of the sample | A325 TC Bolt assys |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | R | Last name of sampler or witnessed by | Parr |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Tru-fit Products | Transportation Laboratory (TL) Number | NA |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-019-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 26975-177742, 399097B, 406668C, 406668A | |
Washer Mfg. Lot Number(s) | D3888, 031905, 032502, 032338 | Bolt Specification | A325 TC |
Bolt Length(s) | 1.75, 1.75, 2, 2.25 | Nut Specification | A563 |
Washer Specification | F436 | Finish | Plain |
Diameter/Size | .625, .75 | Bolt Mfg. Lot Number | 26986-10498480, 400776B, 407384E, 405337B |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-10-12-13
DIME Test ID: 2018-10-12-13-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-11-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/24/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 2B | 399097B | 3/4\" | 59119 | 262.97 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 10/25/2018 ✔