Summary for Test 2018-10-03-24-76
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
| Award Date | 03/12/2018 |
| Closeout Date | 10/05/2020 |
| Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
| Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
| QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
| Sample Taken Date | 10/03/2018 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2018 |
| Sample type | Quality Assurance | A brief description of the sample | fastener Assembly |
| The quantity of what the sample constitutes | 8 Rocaps | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Structural Steel Products | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S43-046-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 091718D, 091718E, 091718B, 091718F, 091718G, 142, 143 |
|---|---|---|---|
| Heat Number(s) | NA | Nut Mfg. Lot Number(s) | 406665A, 402866A, 363890A, 23501-166333 |
| Washer Mfg. Lot Number(s) | D3078, D4240, D2602, D4382 | Bolt Specification | A325 |
| Bolt Length(s) | 2.25, 2.5, 1.5, 2.75, 3.75, 4, 4.25 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | .75, .625, .5, 1.25, 1.5 | Bolt Mfg. Lot Number | 406659B, 404840A, 404784A, 400036A, 361722A, |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-10-03-24
DIME Test ID: 2018-10-03-24-76
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-10-30
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 10/22/2018
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: D3078
Finish Coating: ASTM B695 - Mech Galv
Product Markings: P F436
Size: .75 in
Bolt Length: no data
Measurement Average: 3.4 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/23/2018 ✔