Summary for Test 2018-10-03-24-12
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212562 DEA: 024G5504 EFIS: 0214000036 |
|---|---|
| DIST-CO-RTE-PM | 02-SIS-5-2.7/R11.4 |
| Award Date | 03/12/2018 |
| Closeout Date | 10/05/2020 |
| Work Description | RECONSTRUCT WITH HMA AND PCC, WIDEN STRUCTURE AND UPGRADE RAILS |
| Location Description | SISKIYOU COUNTY IN AND NEAR DUNSMUIR FROM SACRAMENTO RIVER BRIDGE TO 0.6 MILE SOUTH OF NORTH MOUNT SHASTA UNDERPASS |
| QA Service Level | 1 (Verified on 04/04/2018) |
Sample Information
| Sample Taken Date | 10/03/2018 | Sample Unique Key | 24 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2018 |
| Sample type | Quality Assurance | A brief description of the sample | fastener Assembly |
| The quantity of what the sample constitutes | 8 Rocaps | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Adame |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Structural Steel Products | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S43-046-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 091718D, 091718E, 091718B, 091718F, 091718G, 142, 143 |
|---|---|---|---|
| Heat Number(s) | NA | Nut Mfg. Lot Number(s) | 406665A, 402866A, 363890A, 23501-166333 |
| Washer Mfg. Lot Number(s) | D3078, D4240, D2602, D4382 | Bolt Specification | A325 |
| Bolt Length(s) | 2.25, 2.5, 1.5, 2.75, 3.75, 4, 4.25 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | .75, .625, .5, 1.25, 1.5 | Bolt Mfg. Lot Number | 406659B, 404840A, 404784A, 400036A, 361722A, |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-10-03-24
DIME Test ID: 2018-10-03-24-12
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-10-30
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/19/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 7A | 28401-75070887 | 1 1/2\" | 214090 | 952.31 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 10/23/2018 ✔