Summary for Test 2018-10-05-18-4
Test performed: AASHTO T269-14Project Information
| Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 10/05/2018 | Sample Unique Key | 18 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/03/2018 | Sample type | Quality Control |
| A brief description of the sample | THINH | The quantity of what the sample constitutes | 1 |
| From where was the sample collected | Source | First name of sampler or witnessed by | THINH |
| Last name of sampler or witnessed by | NGUYEN | Title of sampler | Unknown |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | AAAA |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | Not set |
| Sublot number | Not set | HMA Mix Number | Not set |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set | HMA Pay | No |
Test Details
DIME Sample ID: 2018-10-05-18
DIME Test ID: 2018-10-05-18-4
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2018-10-26
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: David Phong
Date of test: 10/03/2018
| 1 | 2 | 3 | |
|---|---|---|---|
4.0 % | 3.9 % | 3.9 % | |
4.0 % |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2018 ✔