Summary for Test 2018-10-02-28-1
Test performed: AASHTO T27-14Project Information
Project Identifiers | Project ID: 9999 DEA: 00000000 EFIS: 0000000000 COOP: 99999333399 MINOR: 333333 Permit Numbers: 555555 0400NRT0000 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME DEVELOPERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | 1 (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 10/02/2018 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/12/2018 |
Sample type | Quality Control | A brief description of the sample | 1 |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Source |
First name of sampler or witnessed by | thinh | Last name of sampler or witnessed by | nguyen |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | aaa | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 1111 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | aa |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-10-02-28
DIME Test ID: 2018-10-02-28-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-10-26
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: David Phong
Date of test: 10/04/2018
Cumulative percent passing the 1 1/2 in. sieve: 0 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 79.4 %
Cumulative percent passing the 3/8 in. sieve: 29.4 %
Cumulative percent passing the 1/4 in. sieve: 0 %
Cumulative percent passing the #4 sieve: 1 %
Cumulative percent passing the #8 sieve: 1 %
Cumulative percent passing the #16 sieve: 1 %
Cumulative percent passing the #30 sieve: 1 %
Cumulative percent passing the #50 sieve: 1 %
Cumulative percent passing the #100 sieve: 1 %
Cumulative percent passing the #200 sieve: 0.9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/19/2018 ✔