Summary for Test 2018-10-04-2-16

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Sample Information

Sample Taken Date10/04/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing10/10/2018 Sample typeQuality Assurance
A brief description of the sample7/8 A325 Bolt Assembly The quantity of what the sample constitutes1 Lot
From where was the sample collectedDistributor First name of sampler or witnessed byScott
Last name of sampler or witnessed byLeavitt Title of samplerQA Inspector
Telephone number of sampler510 590-0116 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUtah Pacific Bridge
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormS28-235-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0104413, TT0104414, TT0104415
Heat Number(s)10553610, 20495670, 10538920 Nut Mfg. Lot Number(s)28478-S-188310
Washer Mfg. Lot Number(s)D5881, 783Z30 Bolt SpecificationA325
Bolt Length(s)2-3/4, 3, 3-1/4 Nut SpecificationA563 DH
Washer SpecificationF436, F959 FinishHDG, HDG, HDG
Diameter/Size7/8, 7/8, 7/8 Bolt Mfg. Lot NumberBG1246, BG0925, BG1193
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-10-04-2
DIME Test ID: 2018-10-04-2-16
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-10-25

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 10/18/2018
Sample No.: 1C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 28478-S-188310
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: U DH
Size: .875 in
Bolt Length: no data
Measurement Average: 5.1 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/18/2018 ✔