Summary for Test 2018-09-26-8-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 210569
DEA: 083555V4
EFIS: 0814000086
DIST-CO-RTE-PM08-SBD-15-42.5/46.0
Award Date11/05/2015
Closeout Date01/18/2022
Work DescriptionWIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR.
Location DescriptionSAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING
QA Service Level1 (Verified on 10/15/2015)

Sample Information

Sample Taken Date09/26/2018 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing10/10/2018 Sample typeQuality Assurance
A brief description of the sampleASTM A325 1" Dia The quantity of what the sample constitutesunknown
From where was the sample collectedJob Site First name of sampler or witnessed byRavinder
Last name of sampler or witnessed bySingh Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameunknown
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)371124B
Washer Mfg. Lot Number(s)D1177 Bolt SpecificationA325 TC
Bolt Length(s)3" Nut SpecificationA563 DH
Washer SpecificationF436 FinishB695
Diameter/Size1" Bolt Mfg. Lot Number378870A
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-09-26-8
DIME Test ID: 2018-09-26-8-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-10-25

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/18/2018
UTM: 400KIP
Temperature: 72 F
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
12A369069B1\"94343419.66Nut ProofFred

General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Partner Data Point File

Test was verified on 10/18/2018 ✔