Summary for Test 2018-10-04-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Sample Information

Sample Taken Date10/04/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing10/10/2018 Sample typeQuality Assurance
A brief description of the sample7/8 A325 Bolt Assembly The quantity of what the sample constitutes1 Lot
From where was the sample collectedDistributor First name of sampler or witnessed byScott
Last name of sampler or witnessed byLeavitt Title of samplerQA Inspector
Telephone number of sampler510 590-0116 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameUtah Pacific Bridge
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormS28-235-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0104413, TT0104414, TT0104415
Heat Number(s)10553610, 20495670, 10538920 Nut Mfg. Lot Number(s)28478-S-188310
Washer Mfg. Lot Number(s)D5881, 783Z30 Bolt SpecificationA325
Bolt Length(s)2-3/4, 3, 3-1/4 Nut SpecificationA563 DH
Washer SpecificationF436, F959 FinishHDG, HDG, HDG
Diameter/Size7/8, 7/8, 7/8 Bolt Mfg. Lot NumberBG1246, BG0925, BG1193
Rocap Test Requirement(s)Yes Lubricant Requirements(s)Yes
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-10-04-2
DIME Test ID: 2018-10-04-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-10-25

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/18/2018
UTM: 400KIP
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11ABG12467/8\"6520029010A325Fred

General comments (publicly viewable) (Max 1000 characters): A325
Test Graph
Source: Partner Data Point File

Test was verified on 10/18/2018 ✔