Summary for Test 2018-10-08-2-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 213248 DEA: 042K0104 EFIS: 0416000341 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-24,80,580,880,980-VAR |
| Award Date | 05/17/2018 |
| Closeout Date | 10/21/2019 |
| Work Description | PATCH SPALLS AND REPAIR AC APPROACH. |
| Location Description | ALAMEDA COUNTY AT VARIOUS LOCATION |
| QA Service Level | 1 (Verified on 06/20/2018) |
Sample Information
| Sample Taken Date | 10/08/2018 | Sample Unique Key | 2 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/08/2018 | Sample type | Quality Assurance |
| A brief description of the sample | Bartec Couplers | The quantity of what the sample constitutes | 150 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Ed |
| Last name of sampler or witnessed by | Fleming | Title of sampler | TET |
| Telephone number of sampler | 707-310-2029 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Harris Rebar | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-198-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | Nucor |
| Coupler Manufacturer | bartec | Intermediate Assembler or Fabricator | |
| Rebar Size | 6 | Coupler Model | Bartec |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | DL12102191 | Rebar Heat Number(s) | SE1810180901 |
| Rebar Size 2 | 6 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-10-08-2
DIME Test ID: 2018-10-08-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-10-17
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 10/10/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | C01 | #6/19mm | 0.44 | 0 | 42923 | 97552 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 10/10/2018 ✔