Summary for Test 2018-09-27-15-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 209695
DEA: 08347704
EFIS: 0800000616
DIST-CO-RTE-PM08-SBD-SR-58-0/12.9
Award Date11/10/2017
Closeout Date01/14/2021
Work Description(Alternative Delivery) The CMGC project will upgrade SR 58 from 2- to 4-lanes in San Bernardino County from the Kern County line to 7.5 miles east of US-395.
Location DescriptionSR-58 / 395 Kramer Junction project. In San Bernardino County from the Kern County line to 7.5 miles east of US-395.
QA Service Level1 (Verified on 12/01/2017)

Sample Information

Sample Taken Date09/27/2018 Sample Unique Key15
Date that the sample was received by the laboratory/organization performing the testing09/28/2018 Sample typeQuality Assurance
A brief description of the sample6x12 concrete cylinders The quantity of what the sample constitutes2
From where was the sample collectedFabricator First name of sampler or witnessed byLarry
Last name of sampler or witnessed byFrancisco Title of samplerTE Civil
Telephone number of samplerUnknown Laboratory sample identification976-877
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameKIEWITT
Transportation Laboratory (TL) Number92618-87-7 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierlb 018 0087 at 7days break Structure namelb 018 0087 at 7days break
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB18-0087
The truck number from where the sample was collectedna The batch plant ticket number from where the sample was collectedat 550am
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleplant kramer
A detailed description of where the material sample was collectedat 9cy Where the material sample would have been placed if not sampledlb 018 0087 at 7days break
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2018-09-27-15
DIME Test ID: 2018-09-27-15-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-10-12

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MC
Date of test: 10/04/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 21240 lb
Maximum load on cylinder 2: 19880 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 751.3 psi
Compressive strength of cylinder 2: 703.2 psi
Compressive strength (to nearest 10 psi): 730 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/5/2018 ✔