Summary for Test 2018-09-13-1-2

Test performed: ASTM C109-11

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/13/2018 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing09/13/2018 Sample typeAnnual Source Testing
A brief description of the sampleGenesee Fly Ash The quantity of what the sample constitutes1 Bucket
From where was the sample collectedSource First name of sampler or witnessed byUnknown
Last name of sampler or witnessed byUnknown Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationCM185835
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameENX
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeCementitious BrandENX
MillGenesee Type of Cementitious MaterialClass F or N Flyash

Test Details

DIME Sample ID: 2018-09-13-1
DIME Test ID: 2018-09-13-1-2
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2019-01-30

Test Results


Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: SD
Date of test: 10/01/2018
Age of specimen: 13 days
The amount of flow (In percent): 115 %
The amount of water used (In percent): 46 %
Maximum load of 1st specimen (lb): 14391 lb
Maximum load of 2nd specimen (lb): 13717 lb
Maximum load of 3rd specimen (lb): 14218 lb
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Average Compressive strength (to nearest 10 psi) control group: 3870 psi
Compressive strength of 1st specimen (psi): 3598 psi
Compressive strength of 2nd specimen (psi): 3429 psi
Compressive strength of 3rd specimen (psi): 3555 psi
Average Compressive strength (to nearest 10 psi): 3530 psi
Strength Activity Index of Portland Cement per ASTM C311: 91
General comments (publicly viewable) (Max 1000 characters): 7 Day Break
Test Graph
Source: Partner Data Point File
Test graph for Specimen 1 of 3

Source: Partner Data Point File
Test graph for Specimen 2 of 3

Source: Partner Data Point File
Test graph for Specimen 3 of 3

Test was verified on 1/23/2019