Summary for Test 2018-09-14-4-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213267
DEA: 04013584
EFIS: 0416000289
DIST-CO-RTE-PM04-SF-80-8.0/8.3,0.9/1.4
Award Date03/29/2018
Closeout Date12/30/2019
Work DescriptionPier Retention
Location DescriptionIn San Francisco and Alameda Counties on Yerba Buena Island and .4 miles west of Oakland Toll plaza
QA Service Level1 (Verified on 05/01/2018)

Sample Information

Sample Taken Date09/14/2018 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/14/2018
Sample typeQuality Assurance A brief description of the sample10 Rebar Couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byCarlos Last name of sampler or witnessed byTongson
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau, Dayton Superior Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormC Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size10 Coupler ModelBar Lock Stanard Coupler
Coating StandardsASTM A934 epoxy Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)MM17103614 Rebar Heat Number(s)65026641
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-09-14-4
DIME Test ID: 2018-09-14-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-09-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/14/2018
UTM: 2000KIP
Halo ID: Big
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
132#10/32mm1.27011909993779Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 9/14/2018