Summary for Test 2018-09-05-6-1
Test performed: ASTM A884-14Project Information
| Project Identifiers | Project ID: 213078 DEA: 081G6204 EFIS: 0816000031 |
|---|---|
| DIST-CO-RTE-PM | 08-RIV-10,86-Var |
| Award Date | 04/06/2018 |
| Closeout Date | 05/10/2019 |
| Work Description | COLD PLANE, RHMA-G OVERLAY, REPLACE PRECAST SLAB AND LOCALIZED DIG-OUT |
| Location Description | IN RIVERSIDE COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 04/09/2018) |
Sample Information
| Sample Taken Date | 09/05/2018 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/07/2018 |
| Sample type | Quality Assurance | A brief description of the sample | Green Epoxy Dowels |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Peter | Last name of sampler or witnessed by | Koury |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | JC Supply Pro Cast | Transportation Laboratory (TL) Number | C935676 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Dowels | Dowel Metal Heat Number | NA |
|---|---|---|---|
| Dowel Epoxy Batch Number | Unknown | Dowel Coating Specification | ASTM A884 |
| Dowel Size | 1.25 in | Dowel Coating Color | Green |
| Dowel Manufacturer | Unknown | Dowel Coater | JC Supply |
| Release Number | 7202441 | Quality Assurance Code | Unknown |
| Rebar Size (#) | Unknown |
Test Details
DIME Sample ID: 2018-09-05-6
DIME Test ID: 2018-09-05-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A884-14: Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement (Epoxy Coating Thickness)
Test Release Date: 2018-09-17
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 09/07/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 40 mils
First Bar Side 1 mean value: 13.09 mils
First Bar Side 2 mean value: 15.65 mils
Second Bar Side 1 mean value: 11.61 mils
Second Bar Side 2 mean value: 12.1 mils
First Bar Mean: 14.37 mils
Second Bar Mean: 11.86 mils
Total mean value: 13.11 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/10/2018 ✔