Summary for Test 2018-08-30-1-1
Test performed: ASTM F606-14Project Information
| Project Identifiers | Project ID: 212573 DEA: 010B5504 EFIS: 0112000137 |
|---|---|
| DIST-CO-RTE-PM | 01-MEN-162-16.2 |
| Award Date | 09/28/2017 |
| Closeout Date | 10/05/2020 |
| Work Description | RECONSTRUCT ROADWAY, CONSTRUCT SOLDIER PILE AND TIEBACK WALL |
| Location Description | MENDOCINO COUNTY ON ROUTE 162 1 MILE EAST OF MIDDLE FORK EEL RIVER BRIDGE |
| QA Service Level | 1 (Verified on 10/03/2017) |
Sample Information
| Sample Taken Date | 08/30/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/31/2018 |
| Sample type | Verification | A brief description of the sample | anchor bolts |
| The quantity of what the sample constitutes | 6 and 5 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
| Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 801-669-2984 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-177-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
|---|---|---|---|
| Heat Number(s) | DL171103150,DL17105664,10459880 | Nut Mfg. Lot Number(s) | n/a |
| Washer Mfg. Lot Number(s) | n/a | Bolt Specification | A449 |
| Bolt Length(s) | 6" and 4" | Nut Specification | n/a |
| Washer Specification | n/a | Finish | HDG |
| Diameter/Size | 1/2" x 4" , 5/8" x 6" | Bolt Mfg. Lot Number | 79139,79141,97405,97217,97406 |
| Rocap Test Requirement(s) | none | Lubricant Requirements(s) | none |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-08-30-1
DIME Test ID: 2018-08-30-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-09-18
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 09/07/2018
UTM: 400KIP
Temperature: 72
| Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
|---|---|---|---|---|---|---|---|---|---|
| 1 | 2A | A449 All Thread Axial | 0.226 | 31534 | 140 | 139531 | 130815 | 29564 | A449 All Thread |
General comments (publicly viewable) (Max 1000 characters): A449 All Thread
Test Graph
Source: Partner Data Point FileTest was verified on 9/11/2018 ✔