Summary for Test 2018-08-27-11-2
Test performed: ASTM A722-15Project Information
| Project Identifiers | Project ID: 99999 DEA: 0322222 |
|---|---|
| DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
| QA Service Level | (Verified on 04/05/2013) |
Sample Information
| Sample Taken Date | 08/27/2018 | Sample Unique Key | 11 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/27/2018 |
| Sample type | Quality Assurance | A brief description of the sample | R63 Galvanized Hex Nuts |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Carolina | Last name of sampler or witnessed by | Margarito |
| Title of sampler | A METS Rep | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Williams Form Engineering | Transportation Laboratory (TL) Number | C647239 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L73-019-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Rebar Size | ||
| Nut Specification for Threaded Bar | Unknown | System Manufacturer | Unknown |
| Epoxy Coating Color | NA | Threaded Bar Application | |
| Coating Standards | Uncoated | Bar Heat Number(s) | Unknown |
| Nut Heat Number(s) | Unknown | Bar Lot Number | Unknown |
| Nut Lot Number | Unknown | Coupler Heat Number(s) | Unknown |
| Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-08-27-11
DIME Test ID: 2018-08-27-11-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-12-17
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 09/05/2018
UTM: no data
Temperature: no data
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.
Test was verified on 12/10/2018 ✔