Summary for Test 2018-08-24-3-9
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 08/24/2018 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/24/2018 |
Sample type | Quality Assurance | A brief description of the sample | 1 inch A325 Bolts |
The quantity of what the sample constitutes | 20 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 702 917-503 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerald Desmond Bridge | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-169-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 28125-6214552205 / 28125-6214435405 / TN731 / | |
Washer Mfg. Lot Number(s) | D4996Z / D4996 | Bolt Specification | A325 |
Bolt Length(s) | 3", 4", 5", 5-1/2, 6", 3-3/4, 7", 8", and 8-1 | Nut Specification | A563-DH |
Washer Specification | F436 | Finish | Galvanized |
Diameter/Size | 1" | Bolt Mfg. Lot Number | 28054-10537450 / 28065-10541510 / 28058-10541 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-08-24-3
DIME Test ID: 2018-08-24-3-9
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-09-18
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/04/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 5A | 28064 | 1\" | 93502 | 415.9 | 10 | A325 TC | Fred |
General comments (publicly viewable) (Max 1000 characters): A325 TC
Test Graph
Source: Partner Data Point FileTest was verified on 9/11/2018 ✔