Summary for Test 2018-08-22-3-2
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 212956 DEA: 080R3404 EFIS: 0812000072 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-38-30.9 |
| Award Date | 03/06/2018 |
| Closeout Date | 09/30/2019 |
| Work Description | BRIDGE REHABILITATION AND UPGRADE BRIDGE RAILING TO STANDARDS |
| Location Description | SAN BERNARDINO COUNTY NEAR ANGELUS OAKS AT SANTA ANA RIVER BRIDGERAM |
| QA Service Level | 1 (Verified on 05/09/2018) |
Sample Information
| Sample Taken Date | 08/22/2018 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2018 |
| Sample type | Quality Assurance | A brief description of the sample | F3125 GR A325 Fastener Assembly |
| The quantity of what the sample constitutes | 120 Fastener Assemblies | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
| Title of sampler | Associate Steel Inspector | Telephone number of sampler | 310-883-8369 |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | C Fabrication | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-045-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | NA Snug Tight Connection |
|---|---|---|---|
| Heat Number(s) | 3072436 | Nut Mfg. Lot Number(s) | 406664A |
| Washer Mfg. Lot Number(s) | 0118-742 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 4 5/16" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | HDG |
| Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 51790-2 |
| Rocap Test Requirement(s) | NA | Lubricant Requirements(s) | |
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2018-08-22-3
DIME Test ID: 2018-08-22-3-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-09-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/31/2018
UTM: 400KIP
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 406664A | .75 | 50875 | 226.3 | Nut Proof Load | Brian |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 9/5/2018 ✔