Summary for Test 2018-08-22-2-1

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 212956
DEA: 080R3404
EFIS: 0812000072
DIST-CO-RTE-PM08-SBD-38-30.9
Award Date03/06/2018
Closeout Date09/30/2019
Work DescriptionBRIDGE REHABILITATION AND UPGRADE BRIDGE RAILING TO STANDARDS
Location DescriptionSAN BERNARDINO COUNTY NEAR ANGELUS OAKS AT SANTA ANA RIVER BRIDGERAM
QA Service Level1 (Verified on 05/09/2018)

Sample Information

Sample Taken Date08/22/2018 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing08/22/2018 Sample typeQuality Assurance
A brief description of the sampleA449 Anchor Bolt Assembly The quantity of what the sample constitutes100 Anchor Bolt Assemblies
From where was the sample collectedFabricator First name of sampler or witnessed byDavid
Last name of sampler or witnessed byWeeks Title of samplerAssociate Steel Inspector
Telephone number of sampler310-883-8369 Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameC Fabrication
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormL79-044-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)NA
Heat Number(s)3076331 Nut Mfg. Lot Number(s)398326A
Washer Mfg. Lot Number(s)290097 Bolt SpecificationASTM A325
Bolt Length(s)19.5" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHDG
Diameter/Size7/8" Bolt Mfg. Lot Number51790-1
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s) Bolt Mill SupplierNot set
Nut Mill SupplierNot set Washer Mill SupplierNot set

Test Details

DIME Sample ID: 2018-08-22-2
DIME Test ID: 2018-08-22-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2018-09-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/31/2018
UTM: 400KIP
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AA449 Bolt0.4626314828013668412779759042A449 Bolt

General comments (publicly viewable) (Max 1000 characters): A449 Bolt
Test Graph
Source: Partner Data Point File

Test was verified on 9/5/2018 ✔