Summary for Test 2018-08-21-17-3
Test performed: ASTM D624-00-re12Project Information
Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
Award Date | 11/05/2015 |
Closeout Date | 01/18/2022 |
Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 08/21/2018 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/23/2018 |
Sample type | Quality Assurance | A brief description of the sample | Elastomeric Bearing Pad |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Pete | Last name of sampler or witnessed by | Etcheverry |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Scougal Rubber | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM1 - Elastomeric Bearing Pad | Mfg. Lot Number(s) | 16847-1 |
---|---|---|---|
Material/Compound/Elastomer ID | Elastomeric | Samples Representing | 21 |
Description (size) | 1" x 12" x 16" | Comments | Unknown |
Description (Number of Shims) | 2 | Type of Bearing Pad | Steel |
Description (Thickness of Shims) | 14 gage | Manufacturer(s) | Scougal Rubber |
Batch Number | N A |
Test Details
DIME Sample ID: 2018-08-21-17
DIME Test ID: 2018-08-21-17-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D624-00-re12: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomers
Test Release Date: 2018-09-07
Test Results
Number of specimens tested: 3
Input Type: Measured
Tester's full name: Brian
Date of test: 08/29/2018
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.069 in
Sample 1 Tear Strength: 246.4 lbf / in
Sample 2 Median Thickness: 0.072 in
Sample 2 Tear Strength: 208.3 lbf / in
Sample 3 Median Thickness: 0.061 in
Sample 3 Tear Strength: 229.5 lbf / in
UTM: no data
Median of the Tear Strength Values: 229.5 lb/in
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Sample 1
Source: Partner Data Point File
Test graph for Sample 2
Source: Partner Data Point File
Test graph for Sample 3
Test was verified on 8/31/2018 ✔