Summary for Test 2018-07-06-8-3
Test performed: ASTM C127-12Project Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 07/06/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/23/2018 |
Sample type | Quality Assurance | A brief description of the sample | 3/8 LW Hydrolite aggregate |
The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Dong |
Title of sampler | TEC | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | associated ready mix | Transportation Laboratory (TL) Number | C913576 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | signal hill |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | associated ready mix |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | LWSBS5A | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-07-06-8
DIME Test ID: 2018-07-06-8-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM C127-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Coarse Aggregate
Test Release Date: 2018-08-30
Test Results
Basis for relative density testing: Oven Dry
Input Type: Calculated
Tester's full name: Bang Nguyen
Date of test: 08/30/2018
Specific Gravity: 1.65
Density: no data
Absorption: 13.7 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/30/2018 ✔