Summary for Test 2014-04-30-12020708-3
Test performed: ASTM C1064-08Project Information
| Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
| Award Date | 01/03/2013 |
| Closeout Date | 09/07/2018 |
| Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
| Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
| Sample Taken Date | 04/30/2014 | Sample Unique Key | 12020708 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
| Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
| The quantity of what the sample constitutes | 5 cylinders | From where was the sample collected | Source |
| First name of sampler or witnessed by | Sarah | Last name of sampler or witnessed by | Thomson |
| Title of sampler | Not set | Telephone number of sampler | (619) 259-3079 |
| Laboratory sample identification | 2014-04-30-1202 | Linked DIME Sample ID | Not set |
| The fabricator/manufacturer/facility name | Vulcan Mission Valley | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 2014-04-30-1202 | |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 103612F |
|---|---|---|---|
| The truck number from where the sample was collected | 447 | The batch plant ticket number from where the sample was collected | 112010 |
| Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
| A detailed description of where the material sample was collected | RW 316 Soundwall | Where the material sample would have been placed if not sampled | Not set |
| From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-04-30-12020708
DIME Test ID: 2014-04-30-12020708-3
Testing Lab: RMA Group - Rancho Cucamonga
Test Method: ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2014-05-20
Test Results
Input Type: Calculated
Tester's full name: Sarah Thomson
Date of test: 04/30/2014
Temperature: 82 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/20/2014 ✔