Summary for Test 2018-08-13-4-3
Test performed: ASTM A934-13Project Information
| Project Identifiers | Project ID: 212618 DEA: 044G0564 EFIS: 0417000154 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-680-M2.4/M12.4 |
| Award Date | 11/16/2017 |
| Closeout Date | 12/08/2022 |
| Work Description | ROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS |
| Location Description | FREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING |
| QA Service Level | 1 (Verified on 10/16/2017) |
Sample Information
| Sample Taken Date | 08/13/2018 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/20/2018 | Sample type | Quality Assurance |
| A brief description of the sample | A615 Grade 75 Threaded Bar | The quantity of what the sample constitutes | 150 |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Ed |
| Last name of sampler or witnessed by | Fleming | Title of sampler | TET |
| Telephone number of sampler | 707-3102029 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Williams Form Eng | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | B10-180-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
| Threaded Bar Type | Deformed | Rebar Size | |
| Nut Specification for Threaded Bar | A576 | System Manufacturer | Williams Form Eng |
| Epoxy Coating Color | Purple | Threaded Bar Application | Soil Nail |
| Coating Standards | ASTM A934 epoxy | Bar Heat Number(s) | 100890429 100791753 |
| Nut Heat Number(s) | 8296508 | Bar Lot Number | 10089042921 10079175321 |
| Nut Lot Number | 9J1D | Coupler Heat Number(s) | EPOXY TEST ONLY |
| Coupler Grade |
Test Details
DIME Sample ID: 2018-08-13-4
DIME Test ID: 2018-08-13-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-08-31
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/22/2018
Lower spec. limit LSL: 10 mils
Upper spec. limit USL: 15 mils
Bar # for First Bar: 100791753-1
Bar # for Second Bar: 100791753-2
First Bar Side 1 mean value: 14.57
First Bar Side 2 mean value: 14.25
Second Bar Side 1 mean value: 12.74
Second Bar Side 2 mean value: 12.8
First Bar Mean: 14.41
Second Bar Mean: 12.77
Total mean value: 13.59
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/24/2018 ✔