Summary for Test 2018-08-14-3-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 08/14/2018 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/14/2018 |
Sample type | Quality Assurance | A brief description of the sample | A449 Bolts |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 702 917-1503 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Gerald Desmond Bridge | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-146-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412477 |
---|---|---|---|
Heat Number(s) | 16730-10205760Z | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A490 | |
Bolt Length(s) | 6" | Nut Specification | A563 |
Washer Specification | F436 | Finish | Galvanized |
Diameter/Size | 1.250 | Bolt Mfg. Lot Number | 16730-10205760Z |
Rocap Test Requirement(s) | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2018-08-14-3
DIME Test ID: 2018-08-14-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-08-28
Test Results
Number of Bolt Samples: 3
Input Type: Measured
Tester's full name: Glen Weldon
Date of test: 08/21/2018
UTM: 400KIP
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 77A | 16730-10205760Z | 1.25 | 144946 | 0 | 6 | Low Tensile | Brian |
2 | 77B | 16730-1025760Z | 1.25 | 142476 | 0 | 6 | Low Tensile | Brian |
3 | 77C | 16730-1025760Z | 1.25 | 142027 | 0 | 6 | Low Tensile | Brain |
General comments (publicly viewable) (Max 1000 characters): FAILS Retest
Test was verified on 8/21/2018 ✔