Summary for Test 2018-08-13-7-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213153 DEA: 044S7804 EFIS: 0400020145 |
---|---|
DIST-CO-RTE-PM | 04-MRN-1-24.7 |
Award Date | 04/26/2018 |
Closeout Date | 10/17/2019 |
Work Description | REPLACE EXISTING CULVERTS WITH 36' REINFORCED CONCRETE SLAB BRIDGE. |
Location Description | MARIN COUNTY NEAR OLEMA AT 1.8 MILES SOUTH OF SIR FRANCIS DRAKE BOULEVARD |
QA Service Level | 1 (Verified on 06/12/2018) |
Sample Information
Sample Taken Date | 08/13/2018 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2018 |
Sample type | Quality Assurance | A brief description of the sample | coupler |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Janine | Last name of sampler or witnessed by | Marr |
Title of sampler | SR | Telephone number of sampler | 510-385-6764 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Dextra America | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 6 | Coupler Model | 6 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 3183 | Rebar Heat Number(s) | SE18101570 |
Rebar Size 2 | 6 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-08-13-7
DIME Test ID: 2018-08-13-7-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-08-24
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/17/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 1 | #6/19mm | 0.44 | 0 | 42769 | 97202 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/17/2018 ✔