Summary for Test 2018-08-13-7-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213153
DEA: 044S7804
EFIS: 0400020145
DIST-CO-RTE-PM04-MRN-1-24.7
Award Date04/26/2018
Closeout Date10/17/2019
Work DescriptionREPLACE EXISTING CULVERTS WITH 36' REINFORCED CONCRETE SLAB BRIDGE.
Location DescriptionMARIN COUNTY NEAR OLEMA AT 1.8 MILES SOUTH OF SIR FRANCIS DRAKE BOULEVARD
QA Service Level1 (Verified on 06/12/2018)

Sample Information

Sample Taken Date08/13/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/15/2018
Sample typeQuality Assurance A brief description of the samplecoupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJanine Last name of sampler or witnessed byMarr
Title of samplerSR Telephone number of sampler510-385-6764
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDextra America Intermediate Assembler or FabricatorUnknown
Rebar Size6 Coupler Model6
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)3183 Rebar Heat Number(s)SE18101570
Rebar Size 2 6 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-08-13-7
DIME Test ID: 2018-08-13-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2018-08-24

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/17/2018
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#6/19mm0.44-0.00334077692673Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/17/2018