Summary for Test 2018-08-09-4-6
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 212888 DEA: 07202124 EFIS: 0700020870 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-20.9/24.6 |
| Award Date | 02/16/2018 |
| Closeout Date | 05/04/2022 |
| Work Description | PAVEMENT REHABILITATION AND BRIDGE WIDENING |
| Location Description | LOS ANGELES COUNTY IN AND NEAR BELL, VERNON, AND CITY OF COMMERCE, FROM 0.2 MILE SOUTH OF SLAUSON AVENUE OVERCROSSING TO 0.1 MILE NORTH OF THIRD STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 03/29/2018) |
Sample Information
| Sample Taken Date | 08/09/2018 | Sample Unique Key | 4 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/09/2018 | Sample type | Quality Assurance |
| A brief description of the sample | Resistance welded hoops | The quantity of what the sample constitutes | 1005 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Sherri |
| Last name of sampler or witnessed by | Brannon | Title of sampler | QA Inspector |
| Telephone number of sampler | 7077918219 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | CMC Rebar Etiwanda | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L48-084-18 | |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 6503145703 |
| Hoop Manufacturer Lot Number(s) | 1, 5, 7 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 7 |
| Diameter of Hoop | 4'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
| Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2018-08-09-4
DIME Test ID: 2018-08-09-4-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-22
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/14/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 3 | 5 | #7/22mm | 0.6 | 57140 | 95230 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/15/2018 ✔