Summary for Test 2018-08-07-1-2
Test performed: ASTM A722-15Project Information
| Project Identifiers | Project ID: 213126 DEA: 051J6604 EFIS: 0051800009 |
|---|---|
| DIST-CO-RTE-PM | 05-SB-192-8.0/12.5 |
| Award Date | 01/09/2018 |
| Closeout Date | 10/29/2020 |
| Work Description | Replace bridges (3) and bridge rails (2) |
| Location Description | In Santa Barbara County in and near Santa Barbara, Montecito, and Carpinteria. |
| QA Service Level | 1 (Verified on 05/14/2018) |
Sample Information
| Sample Taken Date | 08/07/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/07/2018 |
| Sample type | Verification | A brief description of the sample | ATB 1-3/8 in |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
| First name of sampler or witnessed by | Carolina | Last name of sampler or witnessed by | Margarito |
| Title of sampler | METS Rep | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Williams Form Eng | Transportation Laboratory (TL) Number | C647238 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L73-016-18 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A722 | Threaded Bar Grade | 150 |
| Threaded Bar Type | Deformed | Rebar Size | 11 |
| Nut Specification for Threaded Bar | A29 | System Manufacturer | Williams Form |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | 100786059 |
| Nut Heat Number(s) | 73100031 | Bar Lot Number | Unknown |
| Nut Lot Number | 36Y3D | Coupler Heat Number(s) | Unknown |
| Coupler Grade | Unknown |
Test Details
DIME Sample ID: 2018-08-07-1
DIME Test ID: 2018-08-07-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-08-20
Test Results
Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/13/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Reduction of area (%) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | A722 1-3/8\" Threaded Bar & Nut | L73-016-18 | 1.58 | 163124 | 137959 | 11.8 | 0 | A722 Threaded Bar and Nut | Brian |
General comments (publicly viewable) (Max 1000 characters): A722 Threaded Bar and Nut
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/13/2018 ✔