Summary for Test 2018-05-15-34-9

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 212679
DEA: 023E7204
EFIS: 0200020154
DIST-CO-RTE-PM02-TEH-36-42.1/46.0
Award Date12/18/2017
Closeout Date08/07/2019
Work DescriptionCOLD PLANING, PAVING, MINOR CONCRETE, ELECTRICAL AND STRIPING WORK.
Location DescriptionTEHAMA COUNTY IN AND NEAR RED BLUFF FROM EAST SAND SLOUGH BRIDGE TO 0.6 MILE EAST OF STICE ROAD
QA Service Level1 (Verified on 05/24/2018)

Sample Information

Sample Taken Date05/15/2018 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing05/15/2018 Sample typeVerification
A brief description of the sampleLab Batched 3/4-inch Type G Aggregate, Untreated The quantity of what the sample constitutesJMF Verification
From where was the sample collectedSource First name of sampler or witnessed byMichael
Last name of sampler or witnessed byAllegretto Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationD77390F
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTullis, Inc - Northstate Asphalt - Redding, CA
Transportation Laboratory (TL) Number847538 Inspector Lot Number from the Transportation Laboratory (TL) FormJMF 18-08-S1
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057::SHASTA RANCH AGGREGATES
The fabricator's/manufacturer's product name for the sampleSized Untreated Aggregates The fabricator/manufacturer designation for the sampleL180372
The plant numberUnknown A detailed description of where the material sample was collectedLab-batched from untreated stockpiles
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberJMF 18-08-S1 Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-15-34
DIME Test ID: 2018-05-15-34-9
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2018-08-06

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Cruz and Sweeny
Date of test: 06/12/2018
Bulk dry specific gravity: 2.638
Average uncompacted voids: 49.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/6/2018 ✔