Summary for Test 2018-07-25-19-1

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 212618
DEA: 044G0564
EFIS: 0417000154
DIST-CO-RTE-PM04-ALA-680-M2.4/M12.4
Award Date11/16/2017
Closeout Date12/08/2022
Work DescriptionROADWAY REHAB, BRIDGE REPLACEMENT, RET. WALLS, TOLL SYSTEMS
Location DescriptionFREMONT AND AT SUNOL FROM MISSION BOULEVARD SEPARATION TO KOOPMAN ROAD UNDERCROSSING
QA Service Level1 (Verified on 10/16/2017)

Sample Information

Sample Taken Date07/25/2018 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing08/01/2018 Sample typeQuality Assurance
A brief description of the sample.6in Prestressing Strand The quantity of what the sample constitutes2
From where was the sample collectedDistributor First name of sampler or witnessed byRICK
Last name of sampler or witnessed byBettencourt Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameSumiden Wire
Transportation Laboratory (TL) NumberC874433 Inspector Lot Number from the Transportation Laboratory (TL) FormS25-109-18
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s) Number of CoilsUnknown
Group NumberUnknown Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0544415 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2018-07-25-19
DIME Test ID: 2018-07-25-19-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-08-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/03/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0544415S377005-30.215595245272826.71.88Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/6/2018 ✔