Summary for Test 2018-01-04-8-6
Test performed: ASTM C109-11Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 01/04/2018 | Sample Unique Key | 8 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/04/2018 |
| Sample type | Annual Source Testing | A brief description of the sample | Fly Ash |
| The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
| First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | CM185811 | Linked DIME Sample ID | 2018-02-21-7 |
| The fabricator/manufacturer/facility name | SRMG | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Cementitious | Brand | Salt River Materials Group |
|---|---|---|---|
| Mill | Four Corners | Type of Cementitious Material | Class F or N Flyash |
Test Details
DIME Sample ID: 2018-01-04-8
DIME Test ID: 2018-01-04-8-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C109-11: Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50mm] Cube Specimens)
Test Release Date: 2018-08-03
Test Results
Will control cubes be used per ASTM C311?: yes
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 03/21/2018
Age of specimen: 28 days
The amount of flow (In percent): 117 %
The amount of water used (In percent): 96.7 %
Maximum load of 1st specimen (lb): 18734 lb
Maximum load of 2nd specimen (lb): 18292 lb
Maximum load of 3rd specimen (lb): 18608 lb
Cross sectional area loaded of 1st specimen (sq. inch): 4 in^2
Cross sectional area loaded of 2nd specimen (sq. inch): 4 in^2
Cross sectional area loaded of 3rd specimen (sq. inch): 4 in^2
Average Compressive strength (to nearest 10 psi) control group: 4792
Compressive strength of 1st specimen (psi): 4683.5 psi
Compressive strength of 2nd specimen (psi): 4573 psi
Compressive strength of 3rd specimen (psi): 4652 psi
Average Compressive strength (to nearest 10 psi): 4640 psi
Strength Activity Index of Portland Cement per ASTM C311: 97
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/3/2018 ✔