Summary for Test 2018-07-13-1-10
Test performed: ASTM F606-14aProject Information
| Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
|---|---|
| DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
| Award Date | 02/24/2017 |
| Closeout Date | 03/03/2020 |
| Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
| Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
| QA Service Level | 1 (Verified on 10/08/2013) |
Sample Information
| Sample Taken Date | 07/13/2018 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/19/2018 | Sample type | Department Acceptance |
| A brief description of the sample | A325 HDG Rocap Assembiy | The quantity of what the sample constitutes | various lots |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Stacey |
| Last name of sampler or witnessed by | Davis | Title of sampler | QAI |
| Telephone number of sampler | 562 480-6984 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Structural and Steel Products |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | B362-050-18 |
| Structure unique identifier | Not set | Structure name | Not set |
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | see tl102 | Nut Mfg. Lot Number(s) | See TL102 |
| Washer Mfg. Lot Number(s) | 1/2 D1214 5/8 D1703 3/4 309270 1 1/4 0415-828 1 1/2 C7027M | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 1 3/4 to 4 1/2 | Nut Specification | ASTM A536 |
| Washer Specification | ASTM F436 | Finish | Mechanical Galv |
| Diameter/Size | 1/2 to 1 1/2 | Bolt Mfg. Lot Number | 1/2 x 2 3/4 M4163 5/8 x 2 BM0324 3/4 x 2 1/ |
| Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2018-07-13-1
DIME Test ID: 2018-07-13-1-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2018-08-07
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/26/2018
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 23629-75062832 | 5/8\" | 34511 | 153.51 | Nut Proof Load | Fred |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Partner Data Point FileTest was verified on 7/31/2018 ✔